Rapid measurement and prediction of bacterial contamination in milk using an oxygen electrode
Sonthaya Numthuam1, Hiroaki Suzuki, Junji Fukuda
1University of Tsukuba, Ibaraki, Japan.
Abstract:
An oxygen electrode was used to measure oxygen consumption to determine bacterial contamination in milk. Dissolved oxygen (DO) measured at 10-35 degrees C for 2 hours provided a reasonable prediction efficiency (r > or = 0.90) of the amount of bacteria between 1.9 and 7.3 log (CFU/mL). A temperature-dependent predictive model was developed that has the same prediction accuracy like the normal predictive model. The analysis performed with and without stirring provided the same prediction efficiency, with correlation coefficient of 0.90. The measurement of DO is a simple and rapid method for the determination of bacteria in milk.