Purpose:
To compare two methods of post processing cardiac CT data to measure global ventricular function. Materials and methods. Retrospective study where three readers measured the end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) of the right (n=22) and left (n=44) ventricles, using a 2D method (extrapolated volumetric method, EVM) and a 3D method (direct volumetric method, DVM) after cardiac CT with retrospective ECG gating. Inter- and intraobserver agreement were calculated based on the intraclass correlation coefficient (ICC) with 95% confidence interval (CI95%), and results obtained with each method were compared using the student t test for paired samples.
Results:
Inter- and intraobserver reproducibility were very good for both methods, with ICC ranging between 0.694 and 0.992, without significant difference. For the left ventricle, EDV, ESV and EF were 16653 ml, 8351 ml and 5415% for DVM et de 20361 ml, 11558 ml and 4613% for EVM respectively. Right ventricular values were 15247 ml, 7534 ml, 5013% and 17253 ml, 9940 ml, 439% (p<0,0001).
Conclusion:
The very good inter- and intraobserver reproducibility for both methods validate their use in clinical practice. Volume measurements with DVM are always inferior to volumes with EDM, with inverse relationship for EF measurements.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...