Related Experiment Video
Updated: Jun 26, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
[Sterilizing effect and mechanism of electrolyzed water]
Zhan-dong Ren1, Yu-chan Zhu, Ye Liu
1Department of Chemical and Environmental Engineering, Wuhan Polytechnic University, Wuhan 430023, China.
Objective:
To study the sterilizing effect and mechanism of electrolyzed-oxidizing water (EOW) and electrolyzed-reductive water (ERW) for Bacillus subtilis var. niger (ATCC9372) and Escherichia coli (8099).
Methods:
The generations of EOW and ERW were made in the ion membrane electrolysis cell. The sterilization manner was the suspension quantitative germicidal test.
Results:
The killing rate of EOW for Bacillus subtilis var. niger was 99.59% in 30 minutes and the killing logarithm value was 2.38 log cfu/ml; the killing rate of ERW for Bacillus subtilis var. niger was 94.62% in 60 minutes and the killing logarithm value was 1.27 log cfu/ml; the killing rate of ERW for Escherichia coli was 100% in 30 minutes and the killing logarithm value was 8.26 log cfu/ml. When the available chlorine content (ACC) value in EOW was 74.90 mg/L and killing time was 30 minutes, the killing rate for Bacillus subtilis var. niger was 99.89% and the killing logarithm value was 2.67 log cfu/ml. When the ACC value was 6.82 mg/L, the killing rate for Bacillus subtilis var. niger was 83.30% and the killing logarithm value was 0. 78 log cfu/ml under the same time. When the oxidizing-reductive potential (ORP) and pH values of EOW were 1138 mV and 2.24 respectively, the killing rate for Bacillus subtilis var. niger was 99.99%. When the ORP and pH values of EOW were 883 mV and 5. 43 respectively, the killing rate of Bacillus subtilis var. niger was 99.73%. When the ORP value of ERW is -918 mV, the sterilizing rate for Bacillus subtilis var. niger was 94.62%; when the ORP value is -155 mV, the sterilizing ratio was only 40.19%.
Conclusion:
It indicates that the sterilizing mechanism of EOW is mainly chemical processes (ACC), while the physical factors are auxiliary. The sterilizing mechanism of ERW is physics sterilizing that the mainly factor is ORP.
More Related Videos
09:00Electrochemical Detection of Deuterium Kinetic Isotope Effect on Extracellular Electron Transport in Shewanella oneidensis MR-1
Published on: April 16, 2018
10:03Investigating the Detrimental Effects of Low Pressure Plasma Sterilization on the Survival of Bacillus subtilis Spores Using Live Cell Microscopy
Published on: November 30, 2017
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Theory of Strong Electrolytes
Chemical Agents for Microbial Control
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Electrolysis