Background:
When conducting a treatment intervention, it is assumed that variability associated with measurement of the disease can be controlled sufficiently to reasonably assess the outcome. In this study we investigate the variability of Apnea-Hypopnea Index obtained by polysomnography and by in-home portable recording in untreated mild to moderate obstructive sleep apnea (OSA) patients at a four- to six-month interval.
Methods:
Thirty-seven adult patients serving as placebo controls underwent a baseline polysomnography and in-home sleep study followed by a second set of studies under the same conditions. The polysomnography studies were acquired and scored at three independent American Academy of Sleep Medicine accredited sleep laboratories. The in-home studies were acquired by the patient and scored using validated auto-scoring algorithms. The initial in-home study was conducted on average two months prior to the first polysomnography, the follow-up polysomnography and in-home studies were conducted approximately five to six months after the initial polysomnography.
Results:
When comparing the test-retest Apnea-hypopnea Index (AHI) and apnea index (AI), the in-home results were more highly correlated (r = 0.65 and 0.68) than the comparable PSG results (r = 0.56 and 0.58). The in-home results provided approximately 50% less test-retest variability than the comparable polysomnography AHI and AI values. Both the overall polysomnography AHI and AI showed a substantial bias toward increased severity upon retest (8 and 6 events/hr respectively) while the in-home bias was essentially zero. The in-home percentage of time supine showed a better correlation compared to polysomnography (r = 0.72 vs. 0.43). Patients biased toward more time supine during the initial polysomnography; no trends in time supine for in-home studies were noted.
Conclusion:
Night-to-night variability in sleep-disordered breathing can be a confounding factor in assessing treatment outcomes. The sample size of this study was small given the night-to-night variability in OSA and limited understanding of polysomnography reliability. We found that in-home studies provided a repeated measure of sleep disordered breathing less variable then polysomnography. Investigators using polysomnography to assess treatment outcomes should factor in the increased variability and bias toward increased AHI values upon retest to ensure the study is adequately powered.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Sample Size Calculation
The sample size for the given experiment or sampling effort is fundamental to any study design. Sample size decides the number of...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...