Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
Factors affecting intraocular pressure measured by noncontact tonometer
1Ulucanlar Eye Education and Research Hospital, 1st Ophthalmology Clinic, Ankara, Turkey. lpryzc@yahoo.com
Purpose:
To investigate the mean values of intraocular pressure (IOP) measured with noncontact tonometer (NCT) and evaluate the factors that may affect IOP.
Methods:
A total of 850 subjects who were admitted to our clinic between March 2005 and February 2006 were recruited for the study. Subjects having blepharitis, conjunctivitis, corneal diseases, glaucoma suspicion, or glaucoma were not accepted to the study. All subjects were questioned about systemic diseases. IOP measurement with NCT and central corneal thickness (CCT) with ultrasound pachymetry were performed for each patient between 9 and 11 AM.
Results:
The mean ages of 367 (43.2%) male subjects and 483 (56.8%) female subjects were 43.9+/-18.1 and 40.7+/-18.0 years +/- SD, respectively. Since right and left eye IOP, CCT, and keratometric values were significantly correlated, right eye values were used for statistical purposes. Mean IOP values in males and females were 13.2+/-3.0 and 13.5+/-2.9 mmHg, respectively. Mean CCT values were 552.5+/-34.7 mum for males and 550.1+/-34.3 mum for females. In multiple regression analysis, IOP was found to be associated with gender, refractive error, CCT, and the presence of diabetes mellitus (DM).
Conclusions:
Gender, CCT, the presence of DM, and refractive error may be significantly associated with IOP in this particular population.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Increased Intracranial Pressure l: Introduction
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...