Related Experiment Video
Updated: Jun 26, 2026

Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Rapid detection of drugs in biofluids using atmospheric pressure chemi/chemical ionization mass spectrometry
Lee Chuin Chen1, Yutaka Hashimoto, Hiroko Furuya
1Clean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu, Yamanashi 400-8511, Japan.
Abstract:
We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type of atmospheric pressure chemical ionization (APCI) that used a dielectric barrier discharge (DBD) to generate the metastable helium gas and reagent ions. The sample solution was loaded in a disposable glass pipette, and the volatile compounds were purged by nitrogen gas to be reacted with the metastable helium gas. The electrodes of the DBD were arranged in such a way that the generated glow discharge was confined within the discharge tube and was not exposed to the analytes. A needle held at 100-500 V was placed between the ion-sampling orifice and the discharge tube to guide the analyte ions into the mass spectrometer. After pH adjustment of the biofluid sample, the amphiphilic drugs were in the form of a water-insoluble oil, which could be concentrated on the liquid surface. By gentle heating of the sample to increase the evaporation rate, rapid and sensitive detection of these drugs in raw urine and serum samples could be achieved in less than 2 min for each sample.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
11:14Rapid High-throughput Species Identification of Botanical Material Using Direct Analysis in Real Time High Resolution Mass Spectrometry
Published on: October 2, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry