Driving standards in tracheostomy care: a preliminary communication of the St Mary's ENT-led multi disciplinary team approach
Related Experiment Video
Updated: Jun 26, 2026

Manufacture of a Multi-Purpose Low-Cost Animal Bench-Model for Teaching Tracheostomy
Published on: May 18, 2019
Objectives:
To assess tracheostomy care and improve standards following the introduction of an ENT-led multidisciplinary tracheostomy ward round service.
Design:
Prospective third cycle audit.
Setting:
Tertiary academic London hospital serving an inner city population of multi-ethnic background (St Mary's Hospital, Paddington, London).
Participants:
Patients with a tracheostomy discharged from ITU to general wards. IMPLEMENTED ACTIONS: Establishment of an ENT-led Tracheostomy Multidisciplinary Team (TMDT). Weekly TMDT ward round to manage patients with a tracheostomy. ENT-led educational and training sessions for allied healthcare professionals.
Main Outcome Measures:
Compliance with local tracheostomy care guidelines (St Mary's tracheostomy care bundle) and time to tracheostomy tube decannulation.
Results:
Preliminary results of 10 patients show improved compliance with tracheostomy care guidelines, established in 2004, rising to 94%. Average time to decannulation was significantly reduced from 21 to 5 days (P-value = 0.0005, Mann Whitney Wilcoxon Test). The mean total tracheostomy time was reduced from 34 to 24 days although this was not statistically significant (P-value = 0.13, Mann Whitney Wilcoxon Test).
Conclusions:
The introduction of regular ENT-led multidisciplinary input for patients with a tracheostomy significantly improved compliance with nursing care standards. There was also a reduction in the total length of time tracheostomy tubes remain in situ, with time to decannulation significantly reduced.
Related Concept Videos
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask and...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask