Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Background suppression of electrical activity is a potential biomarker of subsequent brain injury in a rat model of neonatal hypoxia-ischemia.

Journal of neurophysiology·2022
Same author

A rodent model of human organophosphate exposure producing status epilepticus and neuropathology.

Neurotoxicology·2016
Same author

Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves.

Journal of neural engineering·2016
Same author

Mechanisms of Neuronal Silencing After Cortical Spreading Depression.

Cerebral cortex (New York, N.Y. : 1991)·2016
Same author

Temporal progression of evoked field potentials in neocortical slices after unilateral hypoxia-ischemia in perinatal rats: Correlation with cortical epileptogenesis.

Neuroscience·2016
Same author

Ischemic injury suppresses hypoxia-induced electrographic seizures and the background EEG in a rat model of perinatal hypoxic-ischemic encephalopathy.

Journal of neurophysiology·2015

Related Experiment Video

Updated: Jun 26, 2026

Long-term Continuous EEG Monitoring in Small Rodent Models of Human Disease Using the Epoch Wireless Transmitter System
08:43

Long-term Continuous EEG Monitoring in Small Rodent Models of Human Disease Using the Epoch Wireless Transmitter System

Published on: July 21, 2015

A simple quantitative method for analyzing electrographic status epilepticus in rats.

M J Lehmkuhle1, K E Thomson, P Scheerlinck

  • 1Department of Physiology, University of Utah School of Medicine, 420 Chipeta Way, Suite 1700, Salt Lake City, UT 84108, USA.

Journal of Neurophysiology
|January 9, 2009
PubMed
Summary
This summary is machine-generated.

Electrographic status epilepticus (ESE) is a critical condition requiring precise measurement. This study introduces a novel EEG analysis method to objectively quantify ESE, aiding treatment evaluation.

More Related Videos

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy
11:54

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy

Published on: January 29, 2018

Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
08:28

Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus

Published on: April 5, 2011

Related Experiment Videos

Last Updated: Jun 26, 2026

Long-term Continuous EEG Monitoring in Small Rodent Models of Human Disease Using the Epoch Wireless Transmitter System
08:43

Long-term Continuous EEG Monitoring in Small Rodent Models of Human Disease Using the Epoch Wireless Transmitter System

Published on: July 21, 2015

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy
11:54

Simultaneous Video-EEG-ECG Monitoring to Identify Neurocardiac Dysfunction in Mouse Models of Epilepsy

Published on: January 29, 2018

Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
08:28

Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus

Published on: April 5, 2011

Area of Science:

  • Neuroscience
  • Clinical Neurology
  • Biomedical Engineering

Background:

  • Electrographic status epilepticus (ESE) is a severe neurological emergency with variable characteristics and treatment responses.
  • Quantifying ESE components is crucial for research and clinical practice.
  • Existing methods may not adequately capture the dynamic nature of ESE.

Purpose of the Study:

  • To develop and validate a straightforward, quantitative method for assessing ESE.
  • To enable objective evaluation of therapeutic interventions for ESE.
  • To improve the signal-to-noise ratio in electrophysiological recordings of seizure activity.

Main Methods:

  • Utilized a gamma-band frequency range to isolate seizure-related EEG activity.
  • Employed an energy operator and an eighth-order polynomial to quantify EEG spiking.
  • Applied the method to a benzodiazepine-resistant rat model of pilocarpine-induced ESE.

Main Results:

  • The developed method effectively reduced motion artifacts and noise, enhancing EEG spike signal clarity.
  • Demonstrated the ability to quantitatively assess the efficacy of pharmaceutical agents in suppressing ESE.
  • Provided rapid and objective data on short- and long-lasting pharmacological effects.

Conclusions:

  • The novel EEG analysis technique offers an objective, quantitative, and rapid assessment tool for ESE.
  • This method facilitates the evaluation of therapeutic strategies for ESE and similar prolonged seizure activities.
  • The approach is beneficial for both researchers and clinicians managing ESE.