Related Experiment Video
Updated: Jun 26, 2026

Low-cost Custom Fabrication and Mode-locked Operation of an All-normal-dispersion Femtosecond Fiber Laser for Multiphoton Microscopy
Published on: November 22, 2019
Formulation of frequency stability limited by laser intrinsic noise in feedback systems
Teruhito Hori1, Akito Araya, Shigenori Moriwaki
1Earthquake Research Institute, University of Tokyo, 1-1-1 Yayoi, Bunkyo-ku, Tokyo 113-0032, Japan. ukk47113@mail.ecc.u-tokyo.ac.jp
Abstract:
We investigated the influence of amplitude modulation (AM) noise and phase modulation (PM) noise of a laser source on the frequency stability in frequency stabilization systems. We estimated the frequency stability and evaluated the efficacy of a noise reduction technique (the Doppler-trend subtraction method) of a laser diode frequency stabilization system, where enhanced intensity noise arising from PM-to-AM noise conversion through a reference gas cell is reduced using the technique employed in modulation transfer spectroscopy. To evaluate the relationship between the laser's intrinsic noise and its frequency stability, we performed noise spectrum measurements and formulated frequency stability in addition to measuring Allan standard deviation. As a result, it is found that the extra noise generated in PM-to-AM conversion is efficiently removed by the Doppler-trend subtraction method and that within the feedback bandwidth, the frequency stability becomes 1 order of magnitude better than that without the method.
Related Concept Videos
Effects of feedback
Feedback significantly modifies the gain of a control system. The gain of a system without feedback is altered by a factor of one plus GH, where G represents...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
Load-frequency control
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires careful...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...