Influence of image-analysis software on quantitation of two-dimensional gel electrophoresis data
Martina Stessl1, Christian R Noe, Bodo Lachmann
1Department of Medicinal Chemistry, University of Vienna, Austria.
Abstract:
Image analysis of two-dimensional gels is a crucial step in a proteomic workflow and has a direct impact on obtained qualitative and quantitative data. Since the analysis is a complex process and creates large data amounts, the use of a respective software is inevitable. There are only a few papers published addressing the issue of analysis-based variance; therefore, our aim was to highlight the discrepancy of received results when different commercially available image-tools are used for gel analysis especially in terms of comparability of the obtained outcome when the same digital image set is used. A set of six gels (three replicates per group) of real-life samples was created and examined with two different versions of PD-Quest (Bio-Rad) (version 6.1 and its update version 8.0) and with an external image-tool Delta 2D (Decodon) (version 3.6). Replicate groups were analyzed and compared with each other with regard to volume ratios of a group of significantly changed spots. The study points out significant variations among results depending on the software package used, underlining the importance of a careful investigation of post-experimental processes to receive comparable and reliable results.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...