Remo A Crescenti1, Jeffrey C Bamber, Nigel L Bush
1Joint Department of Physics, Institute of Cancer Research and Royal Marsden NHS Foundation Trust, Surrey, SM2 5PT, UK. remo.crescenti@icr.ac.uk
Abstract:
Radiation-sensitive polymer gels for clinical dosimetry have been intensively investigated with magnetic resonance imaging (MRI) because the transversal magnetic relaxation time is dependent on irradiation dose. MRI is expensive and not easily available in most clinics. For this reason, low-cost, quick and easy-to-use potential alternatives such as optical computed tomography (CT), x-ray CT or ultrasound attenuation CT have also been studied by others. Here, we instead evaluate the dose dependence of the elastic material property, Young's modulus and the dose response of the viscous relaxation of radiation-sensitive gels to discuss their potential for dose imaging. Three batches of a radiation-sensitive polymer gel (MAGIC gel) samples were homogeneously irradiated to doses from 0 Gy to 45.5 Gy. Young's modulus was computed from the measured stress on the sample surface and the strain applied to the sample when compressing it axially, and the viscous relaxation was determined from the stress decay under sustained compression. The viscous relaxation was found not to change significantly with dose. However, Young's modulus was dose dependent; it approximately doubled in the gels between 0 Gy and 20 Gy. By fitting a second-order polynomial to the Young's modulus-versus-dose data, 99.4% of the variance in Young's modulus was shown to be associated with the change in dose. The precision of the gel production, irradiation and Young's modulus measurement combined was found to be 4% at 2 Gy and 3% at 20 Gy. Potential sources of measurement error, such as those associated with the boundary conditions in the compression measurement, inhomogeneous polymerization, temperature (up to 1% error) and the evaporation of water from the sample (up to 1% error), were estimated and discussed. It was concluded that Young's modulus could be used for dose determination. Imaging techniques such as elastography may help to achieve this if they can provide a local measurement of Young's modulus, which may eliminate problems associated with the boundaries (e.g. variation in coefficient of friction) and inhomogeneous polymerization. Elastography combined with a calibration should also be capable of mapping dose in three dimensions.
More Related Videos
07:14In situ Photo-rheology Monitors Viscoelastic Changes in Photo-responsive Polymer Networks
Published on: June 20, 2025
13:34High Throughput Traction Force Microscopy Using PDMS Reveals Dose-Dependent Effects of Transforming Growth Factor-β on the Epithelial-to-Mesenchymal Transition
Published on: June 1, 2019
Related Concept Videos
Problem Solving on Stress and Strain
Strain and Elastic Modulus
Plastic Behavior
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Hooke's Law
Molecular Weight of Step-Growth Polymers
As the step-growth polymerization involves step-wise condensation of monomers, the molecular weight also builds up eventually. Consequently, high molecular weight polymers are obtained at the late stages of the polymerization, where 99% of monomers have been consumed.
The extent of the...