1Grantley Stable Neonatal Unit, Royal Brisbane and Women's Hospital, Brisbane, Queensland, Australia. luke_jardine@health.qld.gov.au
Background:
Continuous positive airway pressure (CPAP) is a widely accepted method of respiratory support used in the care of preterm infants. It remains unknown as to what is the best strategy for the withdrawal of CPAP once it has been commenced. The aim of the present survey was to establish the current practices for withdrawal of nasal CPAP used by Australian neonatologists. A secondary aim was to establish what criteria clinicians use as an indicator for failure off CPAP.
Methods:
Surveys were sent to all 124 Australian neonatologists identified by the list of centers in the Australia and New Zealand Neonatal Network.
Results:
A total of 124 surveys were sent; 86 (69%) replies were received, of which 84 (68%) of the respondents had completed the questionnaire. Seventy-one percent of respondents used a graded-time-off CPAP. The majority of babies for whom they used graded-time-off CPAP were deemed to be chronic (79%) or had chronic neonatal lung disease (73%). A total of 74% of respondents had the level of CPAP gradually reduced.
Conclusions:
At least 48% of Australian neonatologists use graded-time-off CPAP. At least 50% of Australian neonatologists wean the level of CPAP prior to cessation. Neonatologists have similar criteria for recommencing CPAP, with the majority considering increased oxygen requirement, increased work of breathing, increased frequency of apnea and increased severity of apnea important indicators.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...