Optimization of the thermal environment of columns packed with very fine particles
Fabrice Gritti1, Georges Guiochon
1Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600, USA.
Abstract:
The apparent reduced HETP (height equivalent to a theoretical plate) of columns packed with very fine 1.7mum BEH-C(18)particles were measured under isocratic conditions, for different thermal conditions applied to the surface wall (column left in still-air at laboratory temperature, column placed in the oven of the Acquity UPLC chromatograph heated at different temperatures, or column immersed in a water stream at different controlled temperatures). The sample was the low-molecular weight, highly diffusive compound naphtho[2,3-a]pyrene. The mobile phase was either pure acetonitrile or a mixture of acetonitrile and water (85/15, v/v). The plot of the measured HETPs versus the mobile phase flow velocity begins to deviate from the classical isothermal van Deemter curve or the advantages of using very fine particles begins to disappear when the heat power released by the friction of the stream percolating through the packed bed exceeds 4W per unit length of column (m). These effects are minimum when (1) the temperature of the column wall is not controlled and the wall remains in contact with air; or (2) a suitable difference between the temperature of the column wall (hot) and the temperature of the entering liquid (cooler) is set by the analyst.
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Principles Of Column Chromatography
Colloidal precipitates
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...