Related Experiment Video
Updated: Jun 26, 2026

Synthesis and Microdiffraction at Extreme Pressures and Temperatures
Published on: October 7, 2013
Synchrotron infrared reflectivity measurements of iron at high pressures
Christopher T Seagle1, Dion L Heinz, Zhenxian Liu
1Department of the Geophysical Sciences, University of Chicago, Chicago, Illinois 60637, USA. seagle@uchicago.edu
Abstract:
The infrared reflectance of iron was studied using high-pressure synchrotron radiation methods up to 50 GPa at room temperature in a diamond anvil cell of 1000-8000 cm(-1) (1.25-10 microm). The magnitude of the reflectivity shows a weak pressure dependence up to the transition from the body centered cubic (alpha) to hexagonal close packed (epsilon) phase transition, where a discontinuous change in both the slope and magnitude of the reflectivity was observed. Reflectance spectra were corrected for diamond absorption and treated with a Kramers-Kronig analysis to extract the optical constants; the emissivity of iron was derived from Kirchoff's law. The pressure and wavelength dependence of the emissivity is characterized by an empirical function for 1.5-1.9 microm; this wavelength range is useful for spectroradiometric temperature measurements from 1000 K up to approximately 2500 K. Alpha-Fe is a nonideal emitter; however, epsilon-Fe behaves as an almost perfect greybody in the infrared up to the highest pressures of the measurements. Temperature measurements based on the spectroradiometry of iron samples should take into account the wavelength dependent emissivity below the alpha-epsilon phase transition at approximately 13 GPa.
More Related Videos
08:42High-Sensitivity Nuclear Magnetic Resonance at Giga-Pascal Pressures: A New Tool for Probing Electronic and Chemical Properties of Condensed Matter under Extreme Conditions
Published on: October 10, 2014
10:01Protein Film Infrared Electrochemistry Demonstrated for Study of H2 Oxidation by a [NiFe] Hydrogenase
Published on: December 4, 2017
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Applications of IR Spectroscopy: Overview
IR Spectrometers
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Frequency Region: X–H Stretching