Related Experiment Video
Updated: Jun 26, 2026

Binocular Dynamic Visual Acuity in Eyeglass-Corrected Myopic Patients
Published on: March 29, 2022
All-distance visual acuity and contrast visual acuity in eyes with a refractive multifocal intraocular lens with
Ken Hayashi1, Motoaki Yoshida, Hideyuki Hayashi
1Hayashi Eye Hospital, Hakata-Ku, Fukuoka, Japan. hayashi-ken@hayashi.or.jp
Purpose:
To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL.
Design:
Comparative, nonrandomized, interventional study.
Participants:
Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL.
Intervention:
All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs.
Main Outcome Measures:
At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances.
Results:
Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P
Conclusions:
A new refractive multifocal IOL with minimal added power provides significantly better intermediate and near VA than does a monofocal IOL; contrast VA and glare VA are not impaired with this multifocal IOL. Visual acuity at all distances with this IOL is not correlated with pupillary diameter or with IOL decentration and tilt.
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...