A comparison of tests for restricted orderings in the three-class case

Todd A Alonzo1, Christos T Nakas, Constantin T Yiannoutsos

  • 1Division of Biostatistics, University of Southern California, Keck School of Medicine 440 E. Huntington Dr, Suite 400, Arcadia, CA 91006, U.S.A. talonzo@childrensoncologygroup.org

Statistics in Medicine
|January 22, 2009
PubMed

Related Concept Videos

Comparison Tests01:28

Comparison Tests

An infinite series composed of positive terms may either approach a finite value or increase without bound. Determining which outcome occurs is a central task in calculus, and comparison tests provide structured methods for making this determination. Rather than evaluating a series directly, these tests relate it to another series whose behavior is already known, allowing conclusions to be drawn through logical comparison.The direct comparison test applies to series with positive terms. If each...
Multiple Comparison Tests01:13

Multiple Comparison Tests

Multiple comparison test, abbreviated as MCT, is a post hoc analysis generally performed after comparing multiple samples with one or more tests. An MCT will help identify a significantly different sample among multiple samples or a factor among multiple factors.
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Comparison between RL and RC circuits01:24

Comparison between RL and RC circuits

An RC circuit consists of resistance and capacitance, while in an RL circuit, capacitance is replaced by an inductor. RL and RC circuits are first-order differential circuits that store energy. An RC circuit stores energy in the electric field, while an RL circuit stores energy in the magnetic field. When connected to a battery, an RC circuit charges the capacitor, causing the current to decrease from maximum to zero upon being fully charged. This increases the voltage across the capacitor from...
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first column of the Routh...
Second Uniqueness Theorem01:16

Second Uniqueness Theorem

Consider a region consisting of several individual conductors with a definite charge density in the region between these conductors. The second uniqueness theorem states that if the total charge on each conductor and the charge density in the in-between region are known, then the electric field can be uniquely determined.
In contrast, consider that the electric field is non-unique and apply Gauss's law in divergence form in the region between the conductors and the integral form to the surface...