Fault tree analysis for integrated and probabilistic risk analysis of drinking water systems

Andreas Lindhe1, Lars Rosén, Tommy Norberg

  • 1Department of Civil and Environmental Engineering, Chalmers University of Technology, SE-412 96 Göteborg, Sweden. andreas.lindhe@chalmers.se

Water Research
|January 23, 2009
PubMed

Related Concept Videos

Design Example: Analyzing Capacity Contours for Flood Risk Assessment01:17

Design Example: Analyzing Capacity Contours for Flood Risk Assessment

Flood risk assessment involves careful planning and analysis to ensure the safety of communities near water retention structures. Capacity contours are a vital tool in this process, as they illustrate the potential spread of water at specific levels in a given area. In the context of building a bund across a small valley, these contours play a critical role in evaluating the safety of nearby residential areas.In this example, the bund is intended to store stormwater in the valley. The engineers...
Design Example: Designing a Residential Plumbing System01:25

Design Example: Designing a Residential Plumbing System

The design of residential plumbing systems requires carefully evaluating water demand, flow rates, and pressure dynamics to ensure both efficiency and reliability. The nature of water flow within pipes is defined by its Reynolds number, which classifies flow as either laminar (smooth) or turbulent.
Single Pipe Systems01:24

Single Pipe Systems

In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are known. The...
Indefinite Integrals01:25

Indefinite Integrals

The water inflow rate into a storage tank is not constant but increases over time. Initially, the pump delivers water at a rate of 5 L/min. However, the inflow rate increases by 2 L/min for each additional minute due to rising pressure or system adjustments. This scenario can be described mathematically by a linear function:It is necessary to integrate the inflow rate function to measure the total volume of water added to the tank over time. The total water volume V(t) is obtained by performing...
Hazard Rate01:11

Hazard Rate

The hazard rate, also known as the hazard function or failure rate, is a statistical measure used to describe the instantaneous rate at which an event occurs, given that the event has not yet happened. From a probabilistic perspective, it represents the likelihood that a subject will experience the event in a very small time interval, conditional on surviving up to the beginning of that interval. In terms of frequency, the hazard rate can be viewed as the ratio of the number of events to the...
Dimensional Analysis01:27

Dimensional Analysis

Dimensional analysis is a valuable technique in fluid mechanics for simplifying complex problems by reducing them into dimensionless groups. These groups capture the essential relationships between the variables involved, allowing researchers and engineers to analyze fluid flow without dealing with each variable individually. This approach reduces the number of independent variables, allowing for easier analysis and better understanding of physical phenomena.
In fluid mechanics, dimensional...