Dual-mode Imaging of Cutaneous Tissue Oxygenation and Vascular Function
Published on: December 8, 2010
Transcutaneous pO2 imaging during tourniquet-induced forearm ischemia using planar optical oxygen sensors
Philipp Babilas1, Philipp Lamby, Lukas Prantl
1Department of Dermatology, Regensburg University Medical Center, Regensburg, Germany. philipp.babilas@klinik.uni-regensburg.de
Background:
Oxygen-dependent quenching of luminescence using transparent planar sensor foils was shown to overcome the limitations of the polarographic electrode technique in an animal model. This method was then transferred to a clinical setting to measure the transcutaneous pO(2) (p(tc)O(2)).
Methods:
In six healthy subjects, a cuff on the upper arm was occluded up to 20 mmHg above systolic pressure and released after 8 min. P(tc)O(2) was measured at the lower arm every 30 s before, during, and up to 20 min after cuff occlusion (40 degrees C applied skin temperature) using luminescence lifetime imaging (LLI) of platinum(II)-octaethyl-porphyrin immobilized in a polystyrene matrix. For validation, the polarographic Clark electrode technique was applied in close proximity, and measurements were conducted simultaneously.
Results:
P(tc)O(2) measurements before (70.8+/-19.1 vs. 66.2+/-7.7 mmHg) and at the end of ischemic (2.7+/-1.2 vs. 3.6+/-1.7 mmHg) and reperfusion phases (72.2+/-3.6 vs. 68.4+/-8.9 mmHg) did not differ significantly using the Clark electrode vs. LLI. At both the initial ischemic and the reperfusion phases, the Clark electrode measured a faster decrease or increase, respectively, in p(tc)O(2) because of the oxygen consumption occurring in this method.
Conclusion:
The presented method provides accurate and reproducible p(tc)O(2) values under changing microcirculatory conditions. The lack of oxygen consumption during measurement allows both a more realistic estimation of p(tc)O(2) than compared with the gold standard and permanent use in regions with critical oxygen supply.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
08:58Cerebral Blood Oxygenation Measurement Based on Oxygen-dependent Quenching of Phosphorescence
Published on: May 4, 2011
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.