Related Experiment Video
Updated: Jun 26, 2026
![Radiosynthesis of 1-(2-[18F]Fluoroethyl)-L-Tryptophan using a One-pot, Two-step Protocol](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F63025.jpg&w=3840&q=50)
Radiosynthesis of 1-(2-[18F]Fluoroethyl)-L-Tryptophan using a One-pot, Two-step Protocol
Published on: September 21, 2021
[Resolution of thyroxine hormone enantiomers by precolumn derivatization with a fluorescent chiral reagent using
Shaodong Jia1, Meina Zhang, Dongri Jin
1Department of Chemistry, Science College of Yanbian University, Yanji 133002, China. jia_shaodong@yahoo.com.cn
Abstract:
A highly fluorescent chiral tagging reagent, R(-)-4-(N,N-dimethylaminosulfonyl)-7-(3-isothiocy-anatopyrrolidino)-2,1,3-benzoxadiazole (R(-)-DBD-PyNCS), was employed for the enantiomer separation of thyroxine hormone, D,L-3,5,3',5'-tetraiodothyronine (T4) and L-3,5,3'-triiodothyronine (T3). The reaction of R(-)-DBD-PyNCS with the thyroxine enantiomers was carried out at 40 degrees C for 20 min under a basic medium surrounding to yield the corresponding pair of diastereomers. No racemization occurs during the tagging reaction under the optimized conditions. Various experimental parameters for the derivatization reaction including the concentration of tagging reagent, reaction temperature and reaction time have been studied in order to get the highest yield of T4/T3 derivatives. The structures of T4/T3 derivatives were identified based on high performance liquid chromatography-mass spectrometry (HPLC-MS) measurement in negative mode. The efficient separation of derivatives have been achieved by isocratic elution with a water-acetonitrile mobile phase containing 1% acetic acid in a reversed-phase column utilizing a conventional fluorescence detector. The calibration curves of L-T3, D,L-T4 were linear over the concentration ranges of 0.0067-0.22 microg/microL and 0.016-0.30 microg/microL, respectively. The limits of detection (S/N = 3) for L-T3 and D,L-T4 were 0.85 microg/mL and 0.02 microg/mL, respectively. The proposed method has been successfully applied to the determination of T3 and T4 in clinical pharmaceutics.
More Related Videos
Related Concept Videos
Racemic Mixtures and the Resolution of Enantiomers
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Properties of Enantiomers and Optical Activity
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...
Prochirality

