Related Experiment Video
Updated: Jun 26, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Wearable monitoring system for chronic cardio-respiratory diseases
Abstract:
In this paper is presented the study leading to the implementation of an innovative sensing textile platform, based on a wearable monitoring system named Wealthy, where novel piezoresistive sensors have been integrated to increase system capability in the field of pulmonary and cardiovascular diseases monitoring. Two different typologies of textile sensors for plethysmograpic measurements have been characterized and compared to evaluate sensors performance, through electro-dynamic laboratory tests and in vivo measurements. The whole system allows continuous remote monitoring of electrocardiogram and impedance pneumography signals through textile electrodes, while piezoresistive fabric sensors placed at the abdominal and thoracic level are able to discriminate between different breathing patterns. All the signals have been acquired simultaneously allowing a comparative control of cardiopulmonary activity and artifact rejection, while a comparative study with standard BIOPAC MP30 respiratory transducers has been performed in basal condition.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Holter Monitor: 24-Hour Monitoring
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...