Related Experiment Video
Updated: Jun 26, 2026

A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis (ALS)
Published on: February 21, 2011
A quadratic particle swarm optimization method for magnetic tracking of tongue motion in speech disorders
Jia Wang1, Xueliang Huo, Maysam Ghovanloo
1NC-Bionics Lab, Department of Electrical and Computer Engineering, NCSU, Raleigh, NC, USA.
Abstract:
We have devised a new magnetic localization technique to accurately track 3-D tongue movements during speech and ingestion. A small permanent magnet secured on the tongue by tissue adhesives, is utilized as a tracer. The magnetic field variations due to tongue motion are detected by three 3-axis magneto-inductive sensor modules outside the mouth, and wirelessly transmitted to a computer for further processing. The tracer is modeled as a magnetic dipole, which position (x, y, z) and orientation (theta, y) are estimated using a quadratic particle swarm optimization (PSO) algorithm. This algorithm provides faster and more reliable computation compared to the linear PSO. Statistical analysis based on hundreds of simulation and experimental results show that using this method, calculations are accelerated by a factor of three and the tracer can be localized in real-time with approximately 1 mm resolution in position and 2 degrees in orientation.
More Related Videos
Related Concept Videos
Motion Of A Charged Particle In A Magnetic Field
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...