This paper describes a novel tape platform ion sensing methodology specific to the detection of cadmium(II) ions in aqueous solution based on assisted ion transfer reactions across a polarized water/organic gel micro-interface. The tape ion sensors were constructed to incorporate the micro-water/polyvinylchloride-2-nitrophenylethyl ether (PVC-NPOE) gel interfaces referred to as ionodes. The sensors have overall thicknesses less than 300 microm, allowing their packaging in a disposable tape format. The detection methodology is based on the selective assisted transfer of the cadmium ion in aqueous phase by ETH 1062 present in the PVC-NPOE gel layer and was first investigated using cyclic voltammetry. Quantitative analysis of cadmium(II) ions in aqueous solution using the tape sensors was then conducted under stop-flow conditions. Detection limits as low as 20 ppb (178 nM) for Cd(II) ions in very small volumes as low as a single 20 microl droplet without any sample preconcentration was achieved in an analysis time of approximately 20s, which could be easily employed for the direct measurement of Cd(II) ion levels in various field applications. The tape ion sensor can also be used in a flow-cell geometry to preconcentrate Cd(II) ions from aqueous samples and further improve the detection limit.
Related Concept Videos
Amperometry: Overview
Potentiometry: Membrane Electrodes
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides and...
Controlled-Current Coulometry: Coulometric Titration