Single-drop micro-extraction and diffuse reflectance Fourier transform infrared spectroscopic determination of
Devsharan Verma1, Santosh Kumar Verma, Manas Kanti Deb
1School of Studies in Chemistry, Pt. Ravishankar Shukla University, Raipur, Chhattisgarh 492 010, India.
Abstract:
The present paper deals with a new micro-extraction procedure for selective separation of Cr(VI) in the form of a metaloxy anionic species namely dichromate (Cr(2)O(7)(2-)) with N(1)-hydroxy-N(1),N(2)-diphenylbenzamidine (HOA) in to dichloromethane and its subsequent and rapid diffuse reflectance Fourier transform infrared spectroscopic (DRS-FTIR) determination employing potassium bromide matrix. The diffuse reflectance Fourier transform infrared spectroscopy gives both qualitative and quantitative information about the dichromate. The determination of chromium is based on the analytical peak selection, among the various vibrational peaks, at 902 cm(-1). The micro-extraction was based on the liquid-liquid solvent extraction (LLSE) principle. The dichromate binds with the nitrogen and oxygen atoms of N(1)-hydroxy-N(1),N(2)-diphenylbenzamidine (HOA) and forms 1:2, Cr(VI):HOA complex in 0.1 mol L(-1) HCl medium. The formation of above complex, in the acidic medium, is confirmed by the appearance of chocolate-brown color in the micro-extract. The speciation studies of Cr(III) and Cr(VI) is done by conversion of Cr(III) into Cr(VI) utilizing H(2)O(2) as an oxidizing agent. The chemistry of pure dichromate and that of its HOA complex is discussed. The limit of detection (LoD) and the limit of quantification (LoQ) of the method are found to be 0.01 microg g(-1) Cr(2)O(7)(2-) and 0.05 microg g(-1) Cr(2)O(7)(2-), respectively. The standard deviation value and the relative standard value at a level of 10 microg Cr(2)O(7)(2-)/0.1g KBr for n=10 is found to be 0.26 microg Cr(2)O(7)(2-) and 2.6%, respectively. The relative standard deviation (n=8 and 6) for the determination of dichromate (Cr(2)O(7)(2-)) in real human biological fluid samples is observed to be in the range 3.1-7.8%.
More Related Videos
05:35Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 18, 2020
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
IR Spectrometers
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...