On the use of HDR 60Co source with the MammoSite radiation therapy system
D Baltas1, G Lymperopoulou, N Zamboglou
1Department of Medical Physics & Engineering, Strahlenklinik, Klinikum Offenbach GmbH, Offenbach am Main, Germany.
Abstract:
This work summarizes Monte Carlo results in order to evaluate the potential of using HDR 60Co sources in accelerated partial breast irradiation (APBI) with the MammoSite applicator. Simulations have been performed using the MCNP5 Monte Carlo Code, in simple geometries comprised of two concentric spheres; the internal consisting of selected concentrations, C, of a radiographic contrast solution in water (Omnipaque 300) to simulate the MammoSite balloon and the external consisting of water to simulate surrounding tissue. The magnitude of the perturbation of delivered dose due to the radiographic contrast medium used in the MammoSite applicator is calculated. At the very close vicinity of the balloon surface, a dose build-up region is observed, which leads to a dose overestimation by the treatment planning system (TPS) which depends on Omnipaque 300 solution concentration (and is in order of 2.3%, 3.0%, and 4.5%, respectively, at 1 mm away from the balloon - water interface, for C=10%, 15%, and 20%). However, dose overestimation by the TPS is minimal for points lying at the prescription distance (d=1 cm) or beyond, for all simulated concentrations and radii of MammoSite balloon. An analytical estimation of the integral dose outside the CTV in the simple geometries simulated shows that dose to the breast for MammoSite applications is expected to be comparable using HDR 60Co and 192Ir sources, and higher than that for 169Yb. The higher enegies of 60Co sources result to approximately twice radiation protection requirements as compared to 169Ir sources. However, they allow for more accurate dosimetry calculation with currently used treatment planning algorithms for 60Co sources, compared to 169Ir.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:25A Dorsal Skinfold Window Chamber Tumor Mouse Model for Combined Intravital Microscopy and Magnetic Resonance Imaging in Translational Cancer Research
Published on: April 12, 2024
Related Concept Videos
Radiation: Applications
The average...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...