How to Build a Laser Speckle Contrast Imaging (LSCI) System to Monitor Blood Flow
Published on: November 11, 2010
Contrast enhancement of speckle patterns from blood in synchrotron X-ray imaging
1Center for Neural Science, Korea Institute of Science and Technology, Republic of Korea.
Abstract:
Hemodynamics has been a very important factor in understanding and diagnosing various vascular diseases. Recently, the X-ray particle image velocimetry (X-ray PIV) method using speckle patterns of blood has been introduced as a new quantitative visualization method for blood flows without any seeding tracer or contrast agents. In this study, the peculiar optical characteristics of blood on the synchrotron X-ray imaging method, which were not presented in previous studies, were investigated in depth and systematically. The experimental conditions required for X-ray PIV application were found to be the distance between the sample and the scintillator ( approximately 40cm), the thickening of the blood sample (>0.3mm), and hematocrit (20.0-80.0%). In addition, we verified that the X-ray PIV method is reliable as an advanced flow velocimetry by comparing the flow rate evaluated from the X-ray PIV result and the input flow rate supplied from a syringe pump with an error of less than 1%. Through this study, based on the understanding of contrast enhancement mechanisms of speckle patterns from blood, we could establish a trustworthy flow visualization method that can be used effectively in hemodynamic studies.
More Related Videos
07:13Assessing Intracardiac Vortices with High Frame-Rate Echocardiography-Derived Blood Speckle Imaging in Newborns
Published on: December 22, 2023
07:20A Novel Approach to Overcome Movement Artifact When Using a Laser Speckle Contrast Imaging System for Alternating Speeds of Blood Microcirculation
Published on: August 30, 2017
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal crystal...
Super-resolution Fluorescence Microscopy
X-ray Imaging
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...