Left ventricular functional analysis with 16- and 64-row multidetector computed tomography: comparison with gated single-photon emission computed tomography
Related Experiment Video
Updated: Jun 26, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Prachi P Agarwal1, Smita Patel, James Corbett
1Division of Cardiothoracic Radiology, Department of Radiology, University of Michigan Hospitals, Ann Arbor, MI 48109-0030, USA. prachia@med.umich.edu
Objective:
To compare the left ventricular (LV) ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) from electrocardiogram-gated computed tomography (CT) to gated single-photon emission computed tomography (SPECT).
Methods:
Fifty-seven patients underwent electrocardiogram-gated multidetector CT and SPECT examinations within a 3-month period, without interim cardiac events. The LV EF, EDV, and ESV were compared.
Results:
There was an excellent correlation between LV EF obtained from CT (60.25% +/- 12.93%) and SPECT (61.90% +/- 14.93%) (r = 0.81), with no significant difference (P = 0.17). Computed tomography-derived EDV and ESV correlated well with SPECT (r = 0.88 and 0.94, respectively). The EDV from SPECT (132.21 +/- 67.10 mL) was significantly lower than that from CT (147.53 +/- 55.03 mL; P = 0.0007); there was a trend for ESV from SPECT (58.39 +/- 61.20 mL) to be lower than that from CT (63.79 +/- 53.58 mL; P = 0.055). The EF, EDV, and ESV correlation of SPECT with the 64-row multidetector CT was better (r = 0.87, 0.89, and 0.96, respectively) than that with the 16-row CT (r = 0.36, 0.66, and 0.49, respectively).
Conclusions:
There is a good correlation between LV EF, EDV, and ESV from gated SPECT and CT (particularly the 64-row CT). The LV volumes are lower on SPECT than on CT.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...