Related Concept Videos

Overview Of Cell Separation And Isolation01:20

Overview Of Cell Separation And Isolation

Cell separation was first achieved in 1964 by S. H. Seal, who separated large tumor cells from the smaller blood cells using filtration. Two years later, Pohl and Hawk performed experiments on how cells respond differently to a nonuniform electric field based on the cell type. Such observations were the inception of cell separation methods, which allow isolating a single cell type from a heterogeneous sample.
Schottky Barrier Diode01:27

Schottky Barrier Diode

Schottky barrier diodes are specialized semiconductor devices characterized by their unique construction. This construction involves combining a metal layer with a moderately doped n-type semiconductor material. This combination leads to the formation of a Schottky barrier, a pivotal element that defines the diode's operational characteristics. The core functionality of Schottky barrier diodes is their capacity to allow current to flow in only one direction due to their distinctive...
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Bioactive compounds from Artemisia dracunculus L. activate AMPK signaling in skeletal muscle.

Biomedicine & pharmacotherapy = Biomedecine & pharmacotherapie·2021
Same author

Dimeric Proanthocyanidins on the Stability of Dentin and Adhesive Biointerfaces.

Journal of dental research·2019
Same author

Biostability of the Proanthocyanidins-Dentin Complex and Adhesion Studies.

Journal of dental research·2016
Same author

Effect of Bioactive Primers on Bacterial-Induced Secondary Caries at the Tooth-Resin Interface.

Operative dentistry·2016
Same author

Dentin biomodification potential depends on polyphenol source.

Journal of dental research·2014
Same author

Pharmacokinetics of 23-epi-26-deoxyactein in women after oral administration of a standardized extract of black cohosh.

Clinical pharmacology and therapeutics·2009

Related Experiment Video

Updated: Jun 25, 2026

Automated Counterflow Centrifugal System for Small-Scale Cell Processing
04:49

Automated Counterflow Centrifugal System for Small-Scale Cell Processing

Published on: December 12, 2019

Binary concepts and standardization in counter-current separation technology.

J B Friesen1, G F Pauli

  • 1Department of Natural Science, Rosary College of Arts and Sciences, Dominican University, River Forest, IL 60305, USA.

Journal of Chromatography. A
|February 11, 2009
PubMed
Summary
This summary is machine-generated.

Standardizing counter-current separation (CS) operation is crucial for omics analysis. This involves instrument design, operation, and outcome representation for efficient, digitized research environments.

More Related Videos

Spatial Separation of Molecular Conformers and Clusters
10:37

Spatial Separation of Molecular Conformers and Clusters

Published on: January 9, 2014

Microfluidic Device for the Separation of Non-Metastatic (MCF-7) and Non-Tumor (MCF-10A) Breast Cancer Cells Using AC Dielectrophoresis
08:33

Microfluidic Device for the Separation of Non-Metastatic (MCF-7) and Non-Tumor (MCF-10A) Breast Cancer Cells Using AC Dielectrophoresis

Published on: August 11, 2022

Related Experiment Videos

Last Updated: Jun 25, 2026

Automated Counterflow Centrifugal System for Small-Scale Cell Processing
04:49

Automated Counterflow Centrifugal System for Small-Scale Cell Processing

Published on: December 12, 2019

Spatial Separation of Molecular Conformers and Clusters
10:37

Spatial Separation of Molecular Conformers and Clusters

Published on: January 9, 2014

Microfluidic Device for the Separation of Non-Metastatic (MCF-7) and Non-Tumor (MCF-10A) Breast Cancer Cells Using AC Dielectrophoresis
08:33

Microfluidic Device for the Separation of Non-Metastatic (MCF-7) and Non-Tumor (MCF-10A) Breast Cancer Cells Using AC Dielectrophoresis

Published on: August 11, 2022

Area of Science:

  • Analytical Chemistry
  • Biotechnology

Background:

  • Counter-current separation (CS) technology faces challenges in adapting to omics analysis, characterized by complex samples and digital research environments.
  • Efficiency in CS relies on standardized operational parameters, akin to a network of binary decisions.

Purpose of the Study:

  • To address the need for standardization in counter-current separation (CS) technology to enhance its suitability for omics analysis.
  • To highlight key areas for standardization, including instrument design, operation, and outcome representation.

Main Methods:

  • Review of current CS engineering solutions, particularly centrifugal force designs.
  • Analysis of critical factors for standardization: instrument design, operational parameters, and graphical representation of results.
  • Exploration of chromatogram types, such as reciprocal symmetry (ReS) plots, for understanding CS operation.

Main Results:

  • Recent CS engineering focuses on centrifugal force to overcome gravitational limitations.
  • Standardization of instrument design, operation, and graphical output (e.g., ReS plots) is essential for CS efficiency.
  • Differences in solid-liquid versus liquid-liquid chromatography mechanisms necessitate tailored standardization approaches.

Conclusions:

  • Standardization of CS is key to its successful integration into the digital omics age.
  • Standardized methods will enable systematic comparison and understanding of different liquid chromatography (LC) technologies within CS.
  • Developing standardized CS protocols will improve its applicability for complex omics data analysis.