Related Experiment Video
Updated: Jun 25, 2026

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Influence of sensor ingestion timing on consistency of temperature measures
Daniel A Goodman1, Robert W Kenefick, Bruce S Cadarette
1US Army Research Institute of Environmental Medicine, Natick, MA 01760, USA.
Purpose:
The validity and the reliability of using intestinal temperature (T int) via ingestible temperature sensors (ITS) to measure core body temperature have been demonstrated. However, the effect of elapsed time between ITS ingestion and T int measurement has not been thoroughly studied.
Methods:
Eight volunteers (six men and two women) swallowed ITS 5 h (ITS-5) and 29 h (ITS-29) before 4 h of varying intensity activity. T int was measured simultaneously from both ITS, and T int differences between the ITS-5 and the ITS-29 over the 4 h of activity were plotted and compared relative to a meaningful threshold of acceptance (+/-0.25 degrees C). The percentage of time in which the differences between paired ITS (ITS-5 vs ITS-29) were greater than or less than the threshold of acceptance was calculated.
Results:
T int values showed no systematic bias, were normally distributed, and ranged from 36.94 degrees C to 39.24 degrees C. The maximum T int difference between paired ITS was 0.83 degrees C with a minimum difference of 0.00 degrees C. The typical magnitude of the differences (SE of the estimate) was 0.24 degrees C, and these differences were uniform across the entire range of observed temperatures. Paired T int measures fell outside of the threshold of acceptance 43.8% of the time during the 4 h of activity.
Conclusions:
The differences between ITS-5 and ITS-29 were larger than the threshold of acceptance during a substantial portion of the observed 4-h activity period. Ingesting an ITS more than 5 h before activity will not completely eliminate confounding factors but may improve accuracy and consistency of core body temperature.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...