Design of packed-fiber solid-phase extraction device for analysis of the drug and its metabolite in plasma
Related Experiment Video
Updated: Jun 25, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Xue-Jun Kang1, Li-Qin Chen, Yan Wang
1Key Laboratory of Child Development and Learning Science, Ministry of Education, Research Center for Learning Science, Southeast University, Nanjing 210096, China. xjkang64@163.com
Abstract:
A mini-column packed with 1 mg electrospun polystyrene nanofibers (about 200 approximately 400 nm in diameter) was designed for simple, fast extraction of drugs, diazepam and its major metabolite, N-desmethyldiazepam for the analysis of them in human and dog plasma. Ttrezodone was selected as internal standard. The drugs adsorbed on the solid phase could be desorpted with 50 microl of the methanol and then monitored by liquid chromatography coupled to an ultraviolet detector. Parameters influencing the extraction efficiency such as fiber packing amount, eluted solvent, and pH of the sample were decided. The time for the pretreatment of 0.5 ml plasma sample was less than 10 min. The detection limits of diazepam and N-desmethyldiazepam in plasma could be as low as 1 microg/L. The intra- and inter-day precision, calculated from quality control (QC) samples, was less than 9.1%. The method was evaluated by its application in determination of dog plasma samples from three beagles after a single dose oral of diazepam. The technique was validated by comparison with conventional plasma analysis. It was observed that the mini-column offers improved limits of detection and reduced sample preparation time as compared to conventional method. For its simplicity and sensitivity, the method may be used in therapeutic drug monitoring and pharmacology study.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process