Intrahepatic delivery of feeds caused by a displaced percutaneous radiological gastrostomy catheter
B V M Dasari1, K R Gardiner, K Khosraviani
1Department of Colorectal Surgery, The Royal Hospitals, Belfast BT12 6BA, UK.
Abstract:
Percutaneous radiological gastrostomy (PRG) is a safe and accepted method of providing enteral nutrition in those with inadequate oral intake. We report a case of PRG that required laparotomy for intrahepatic displacement of a catheter that had been placed inadvertently through the liver under fluoroscopic guidance. Additional ultrasound or CT guidance may help to define a safe tract to avoid liver or colonic injury. Although transhepatic placement is reported to be well tolerated, this case raises concerns of additional morbidity associated with intrahepatic displacement.