Related Experiment Video
Updated: Jun 25, 2026

A Standardized Approach to Extra-Oral and Intra-Oral Digital Photography
Published on: July 22, 2022
Use of standardized, quantitative digital photography in a multicenter Web-based study
Joseph A Molnar1, Wesley K Lew, Derek A Rapp
1Department of Plastic and Reconstructive Surgery, Wake Forest University School of Medicine, Winston-Salem, NC, USA. jmolnar@wfubmc.edu
Standardized digital photography and planimetry offer a cost-effective method for accurately measuring burn wound size. This reliable technique is suitable for multicenter clinical trials and other studies with visual endpoints.
Area of Science:
- Medical imaging
- Burn wound assessment
- Digital photography in clinical trials
Background:
- Accurate wound area quantification is crucial for effective burn care and clinical trial evaluation.
- Traditional methods for wound measurement can be time-consuming and prone to variability.
- Digital tools offer potential for standardized and objective assessment.
Purpose of the Study:
- To develop and evaluate a Web-based system using standardized digital photography and digital planimetry for assessing hand burn depth and wound area.
- To determine the accuracy and reliability of this technique in a multicenter setting.
Main Methods:
- A prospective, randomized, multicenter trial was conducted using standardized digital photography and a custom backdrop with scales.
- Images were processed using Adobe Photoshop for color adjustment and SigmaScan Pro for two-dimensional digital planimetry to calculate wound area.
- A pilot study with model hands confirmed the accuracy of the planimetry technique.
Main Results:
- Digital photography combined with digital planimetry (SigmaScan) and photo enhancement (Adobe Photoshop) provides a simple, cost-effective method for quantifying wound size.
- The SigmaScan program demonstrated accuracy within 4.7% for calculating predetermined areas.
- Images from individuals with no prior photography experience were reliable for clinical evaluation and wound area quantification in dorsal hand burns.
Conclusions:
- Standardized digital photography is a viable quantitative tool for Web-based, multicenter burn care trials.
- This technique can be adapted for other medical studies requiring visual endpoints, enhancing data consistency and accessibility.