Related Experiment Video
Updated: Jun 25, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
Published on: August 30, 2013
Why does it take longer to read digital than film-screen screening mammograms? A partial explanation
Tamara Miner Haygood1, Jihong Wang, Deanna Lane
1Department of Diagnostic Radiology, Unit 1273, The University of Texas M. D. Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, TX 77030-4009, USA. Tamara.Haygood@mdanderson.org
Abstract:
Digital screening mammograms (DM) take longer to interpret than film-screen screening mammograms (FSM). We evaluated what part of the process takes long in our reading environment. We selected cases from those for which timed readings had been performed as part of a previous study. Readers were timed as they performed various computer manipulations on groups of DM cases and as they moved the alternator and adjusted lighting and manual shutters for FSM cases. Subtracting manipulation time from the original interpretation times yielded estimated times to reach a decision. Manipulation times for DM ranged from a low of 11 s when four-view DM were simply opened and closed in a 4-on-1 hanging protocol before moving on to the next study to 113.8 s when each view of six-view DM were brought up 1-on-1, enlarged to 100% resolution, and panned through. Manipulation times for groups of FSM ranged from 8.3 to 12.1 s. Estimated decision-making times for DM ranged from 128.0 to 202.2 s, while estimated decision-making time for FSM ranged from 60.9 to 146.3 s. Computer manipulation time partially explains the discrepancy in interaction times between DM and FSM. Radiologists also appear to spend more time looking at DM than at FSM before making a decision.
Related Concept Videos
Magnetic Resonance Imaging
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

