Multi-Modal Signals for Analyzing Pain Responses to Thermal and Electrical Stimuli
Published on: April 5, 2019
Reliability of a continuous pain score meter: real time pain measurement
Elisabeth M Boormans1, Paul J van Kesteren, Roberto S Perez
1Department of Obstetrics and Gynecology, Onze Lieve Vrouwe Gasthuis, Amsterdam, The Netherlands. e.m.boormans@amc.nl
Abstract:
We present a newly developed continuous pain score meter (CPSM). The CPSM is based on the principles of the visual analog score (VAS), and electronically measures pain score in a continuous, instead of a single, manner. In this study, we determine the test-retest reliability of this meter. Thirty-two healthy volunteers received a reproducible pain stimulus on the right thumbnail and forearm. After a 1-minute interval the procedure was repeated. During the stimulus, pain was continuously measured with the CPSM, providing values of peak continuous pain score (CPS) and area under the CPS curve (AUC CPS). The intra-class correlation coefficient (ICC) and the 95% limits of agreement were used to assess the agreement between measurements. ICC of peak CPS (0.89 and 0.83) and AUC CPS (0.79 and 0.86) for nail and arm showed a good reproducibility. This study has successfully established the test-retest reliability of the CPSM. The real-time continuous pain measurement may provide more detailed information on a subjects' pain perception compared to a single VAS, in particular during an interval of pain stimuli.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement