Related Experiment Video
Updated: Jun 25, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Light transmission through fiber post: the effect on adhesion, elastic modulus and hardness of dual-cure resin cement
Ivana Radovic1, Gabriele Corciolani, Elisa Magni
1Clinic for Pediatric and Preventive Dentistry, Faculty of Dentistry, University of Belgrade, Dr. Subotica 11, Beograd 11000, Serbia. ivana.radovic@iritel.com
Objectives:
The aim of this study was to investigate the effect of fiber post light transmitting ability to the continuity of resin cement-root dentin (C-RD) and resin cement-fiber post (C-FP) interface, elastic modulus and hardness of a dual-cure resin cement.
Methods:
Spectrophotometric measurements were applied for the determination of light transmission at coronal, middle and apical level as well as at the apical tip through Tech 21 X-OP (TECH) and DT Light Post (DT). Posts were cemented using dual-cured resin cement (Calibra). Roots were sectioned longitudinally through the post. Epoxy resin replicas were made and used to evaluate C-RD and C-FP interface under SEM. Modulus of elasticity (E) and Vicker's hardness (VH) of the cement layer were assessed.
Results:
No light transmission was detected through TECH. Light transmission through DT decreased from coronal to apical and rose at the apical tip. TECH presented a significantly lower percentage of continuous C-RD and C-FP interface in comparison to DT. Coronal third of C-RD interface in TECH specimens had a significantly higher percentage of continuity than apical third. No regional differences in continuity of C-RD interface were found in DT specimens. E and VH were significantly lower when TECH was used, and decreased from coronal to apical for both posts.
Significance:
Cementation of fiber post with no light transmitting ability using a dual-cured resin cement resulted in lower E and VH of the cement layer, and lower percentage of continuous C-RD and C-FP interface in comparison to cementation of light transmitting fiber post.
Related Concept Videos
Fiber Reinforced Concrete
Accelerated Curing of Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...