Increased metabolic activity in abdominal aortic aneurysm detected by 18F-fluorodeoxyglucose (18F-FDG) positron
C W Kotze1, L J Menezes, R Endozo
1Department of Vascular Surgery, Brighton & Sussex University Hospitals NHS Trust, Brighton, East Sussex, UK. carl.kotze@gmail.com
Objectives:
Abdominal aortic aneurysms (AAAs) are associated with an inflammatory cell infiltrate and enzymatic degradation of the vessel wall. The aim of this study was to detect increased metabolic activity in the wall of the AAA with 18F-fluorodeoxyglucose ((18)F-FDG), mediated by glucose transporter protein (GLUTs), using a dedicated hybrid PET/64-detector CT. DESIGN, METHOD AND MATERIALS: 14 patients (All male, mean age 73.6 years, range 61-82) with AAA under surveillance underwent PET/CT scanning with 175 MBq of intravenous (18)F-FDG. The maximum aneurysm diameter and calcification score were determined on the attenuation correction CT. A volume of interest was placed on the aneurysm sac and the maximum Standardised Uptake Value (SUV(max)) measured.
Results:
The mean aneurysm diameter was 5.4 cm (SD+/-0.8). Two aneurysms had the CT characteristics of inflammatory aneurysms. Twelve aneurysms showed increased FDG uptake (SUV(max)>2.5). There was no significant difference in FDG uptake between heavily calcified aneurysms and non-heavily calcified aneurysms (t-test). There was a significant increase in the FDG uptake in the two inflammatory aneurysms compared to the other twelve aneurysms (t-test; P=0.04).
Conclusion:
The findings in this study offer in vivo evidence that the AAA wall shows increased glucose metabolism, mediated by the GLUTs: this increased metabolic activity as detected by PET/CT may be present in most AAAs.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:30Whole Body and Regional Quantification of Active Human Brown Adipose Tissue Using 18F-FDG PET/CT
Published on: April 1, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT)](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)