A linear array, scintillation crystal-photodiode detector for megavoltage imaging.

E J Morton1, W Swindell, D G Lewis

  • 1Joint Department of Physics, Institute of Cancer Research, Sutton, Surrey, England.

Medical Physics
|July 1, 1991
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

An end-to-end assessment on the accuracy of adaptive radiotherapy in an MR-linac.

Physics in medicine and biology·2021
Same author

The stability of imaging biomarkers in radiomics: a framework for evaluation.

Physics in medicine and biology·2019
Same author

CMOS Active Pixel Sensors as energy-range detectors for proton Computed Tomography.

Journal of instrumentation : an IOP and SISSA journal·2017
Same author

Thresholds of biodiversity and ecosystem function in a forest ecosystem undergoing dieback.

Scientific reports·2017
Same author

The UK HeartSpare Study (Stage II): Multicentre Evaluation of a Voluntary Breath-hold Technique in Patients Receiving Breast Radiotherapy.

Clinical oncology (Royal College of Radiologists (Great Britain))·2016
Same author

An experimental demonstration of a new type of proton computed tomography using a novel silicon tracking detector.

Medical physics·2016

A new imaging device uses zinc tungstate crystals for radiotherapy imaging. This system offers high resolution and fast image acquisition during external photon-beam treatments.

Area of Science:

  • Medical Physics
  • Radiotherapy Technology
  • Imaging Science

Background:

  • External photon-beam radiotherapy requires precise imaging for treatment verification.
  • Existing imaging methods may have limitations in resolution, speed, or dose.
  • Accurate patient positioning and setup verification are critical in radiotherapy.

Purpose of the Study:

  • To develop and characterize a novel imaging device for real-time image acquisition during radiotherapy.
  • To evaluate the performance of the imaging device in terms of spatial and contrast resolution.
  • To assess the potential of the device for improving radiotherapy setup verification.

Main Methods:

  • A linear array of 128 zinc tungstate (ZnWO4) scintillation crystals coupled to photodiodes was constructed.

Related Experiment Videos

  • Image acquisition was performed by scanning the detector array across the radiation field using a microcomputer-controlled stepping motor.
  • Image processing, archiving, and analysis were conducted using a microVAX II computer.
  • Main Results:

    • The imaging device achieved image acquisition in under 4 seconds.
    • A contrast resolution better than 1% was obtained at a spatial resolution of 2.5 mm in the object plane.
    • The detector's mechanical design ensures positioning accuracy within 1 mm of the treatment source.

    Conclusions:

    • The developed imaging device is capable of acquiring high-resolution images during external photon-beam radiotherapy.
    • The system's speed and accuracy facilitate efficient setup verification and analysis of treatment variations.
    • This technology has the potential to enhance the precision and safety of radiotherapy delivery.