Related Experiment Video
Updated: Jun 25, 2026

Automated Joint Space Detection Improves Bone Segmentation Accuracy
Published on: November 28, 2025
Automatic segmentation of the ribs, the vertebral column, and the spinal canal in pediatric computed tomographic
Shantanu Banik1, Rangaraj M Rangayyan, Graham S Boag
1Department of Electrical and Computer Engineering, Schulich School of Engineering, University of Calgary, 2500 University Drive NW, Calgary, AB, Canada.
Abstract:
We propose methods to perform automatic identification of the rib structure, the vertebral column, and the spinal canal in computed tomographic (CT) images of pediatric patients. The segmentation processes for the rib structure and the vertebral column are initiated using multilevel thresholding and the results are refined using morphological image processing techniques with features based on radiological and anatomical prior knowledge. The Hough transform for the detection of circles is applied to a cropped edge map that includes the thoracic vertebral structure. The centers of the detected circles are used to derive the information required for the opening-by-reconstruction algorithm used to segment the spinal canal. The methods were tested on 39 CT exams of 13 patients; the results of segmentation of the vertebral column and the spinal canal were assessed quantitatively and qualitatively by comparing with segmentation performed independently by a radiologist. Using 13 CT exams of six patients, including a total of 458 slices with the vertebra from different sections of the vertebral column, the average Hausdorff distance was determined to be 3.2 mm with a standard deviation (SD) of 2.4 mm; the average mean distance to the closest point (MDCP) was 0.7 mm with SD = 0.6 mm. Quantitative analysis was also performed for the segmented spinal canal with three CT exams of three patients, including 21 slices with the spinal canal from different sections of the vertebral column; the average Hausdorff distance was 1.6 mm with SD = 0.5 mm, and the average MDCP was 0.6 mm with SD = 0.1 mm.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Vertebral Column: Regions and Curvature
Regions of the Vertebral Column
In an adult, the spine is subdivided into five regions: the cervical, the thoracic, the lumbar, the sacral, and the coccygeal region. The spine initially develops as a series of 33 vertebrae; after 20 years of age, the nine bones in the sacral region, five sacral, and four coccygeal bones fuse to form the...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...