Related Experiment Video
Updated: Jun 25, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
A new technique to improve cup inclination accuracy in primary total hip arthroplasty
A Gonzalez Della Valle1, B Beksac, M G E Peterson
1Department of Orthopaedics, Hospital for Special Surgery, New York, USA. gonzaleza@hss.edu
Abstract:
Accurate inclination and anteversion of the acetabular component is paramount to achieve a stable total hip arthroplasty, prevent prosthetic dislocation and minimize long- term wear. We present and evaluate a simple new technique to improve consistency in cup inclination during primary total hip arthroplasty, based on information available from the preoperative plan. The technique consists of assessing the distance and relationship between the inferomedial border of the acetabular cup and the inferomedial margin of the teardrop, with the use of a measuring probe. This simple surgical gesture improved consistency in cup inclination during total hip arthroplasty.;
