Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Diagnostic performance of CT/MRI LI-RADS radiation treatment response algorithm v2024 for Y-90 radioembolization.

European journal of radiology·2026
Same author

Somatostatin receptor PET response assessment framework for patients with neuroendocrine tumours (V1.0): a modified Delphi consensus from the European Neuroendocrine Tumor Society (endorsed by EANM and NANETS).

The Lancet. Oncology·2026
Same author

Dynamic Changes in Tumor Burden in Patients Undergoing PSMA RLT.

European urology oncology·2026
Same author

Reply to: Prostate-Specific Membrane Antigen Positron Emission Tomography and Radiometabolic Therapies in Metastatic Castration-Resistant Prostate Cancer.

Journal of clinical oncology : official journal of the American Society of Clinical Oncology·2026
Same author

Targeting Fibroblast Activation Protein with [177Lu]Lu-FAP-2286 in Patients with Advanced Solid Tumors in the Phase I LuMIERE Trial.

Clinical cancer research : an official journal of the American Association for Cancer Research·2026
Same author

Reply: A Call for High-Level Evidence Before Routine Implementation of Posttreatment SPECT.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2026

Related Experiment Video

Updated: Jun 25, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

Initial experience characterizing a type I endoleak from velocity profiles using time-resolved three-dimensional

Thomas A Hope1, Christopher K Zarins, Robert J Herfkens

  • 1Department of Radiology, University of California San Francisco, San Francisco, CA 94143, USA. tom.hope@radiology.ucsf.edu

Journal of Vascular Surgery
|February 19, 2009
PubMed
Summary

This report describes the first use of advanced 4D flow MRI to visualize and analyze a type I endoleak, a common complication following endovascular aneurysm repair. By capturing both detailed 3D structure and blood flow velocity over time, this imaging technique offers a new way to detect and understand these leaks more effectively than standard methods.

Keywords:
vascular imaginghemodynamicsmagnetic resonance angiographyaortic aneurysm

Frequently Asked Questions

More Related Videos

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
11:16

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging

Published on: February 25, 2022

Related Experiment Videos

Last Updated: Jun 25, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
11:16

In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging

Published on: February 25, 2022

Area of Science:

  • Vascular surgery outcomes research within 4D flow magnetic resonance imaging
  • Diagnostic radiology and medical imaging physics

Background:

Endovascular aneurysm repair remains a standard treatment for abdominal aortic aneurysms despite the risk of postoperative complications. Type I endoleaks represent a significant clinical concern because they allow pressurized blood to enter the aneurysm sac. Clinicians currently rely on computed tomography or ultrasound to monitor these patients for potential failure. However, these conventional modalities often struggle to provide comprehensive hemodynamic data regarding the leak's specific flow characteristics. No prior work had resolved the utility of advanced magnetic resonance techniques for this particular diagnostic challenge. That uncertainty drove the exploration of novel imaging protocols to improve patient surveillance. This report addresses the knowledge gap by evaluating a specialized magnetic resonance imaging approach. Researchers aimed to determine if this technology could offer superior insights into complex vascular flow patterns.

Purpose Of The Study:

The aim of this report is to evaluate the utility of 4D flow magnetic resonance imaging for characterizing type I endoleaks. This study addresses the limitations of current diagnostic tools in monitoring patients after endovascular aneurysm repair. The researchers sought to determine if time-resolved velocity data could improve the detection of these vascular complications. They hypothesized that integrating spatial and temporal information would provide a more accurate assessment than standard imaging. The team focused on the specific challenge of visualizing blood flow within the aneurysm sac. This investigation was motivated by the need for more precise surveillance protocols in vascular surgery. No prior work had successfully applied this specific magnetic resonance technique to this clinical problem. The authors intended to establish a proof-of-concept for this advanced diagnostic approach in a real-world setting.

Main Methods:

The review approach involved the first clinical application of time-resolved three-dimensional phase-contrast magnetic resonance imaging. Investigators implemented a protocol that synchronized spatial mapping with velocity quantification. This design focused on capturing the dynamic nature of blood movement within the vascular space. The team utilized standard magnetic resonance angiography to establish a baseline anatomical reference. They then layered the phase-contrast data over these structural images to create a comprehensive hemodynamic model. This methodology prioritized the acquisition of high-resolution temporal information during the cardiac cycle. The approach allowed for the visualization of complex flow patterns that are typically invisible to static imaging. Researchers systematically compared these findings against established diagnostic criteria for vascular leaks.

Main Results:

Key findings from the literature indicate that 4D flow magnetic resonance imaging successfully visualizes type I endoleaks. The primary outcome demonstrates the feasibility of obtaining temporally resolved velocity data in a clinical setting. This technique provides a three-dimensional resolution that exceeds the capabilities of traditional Doppler ultrasound. The integration of phase-contrast data with standard angiography allows for precise localization of the leak site. Researchers observed that the velocity profiles clearly delineate the path of blood entering the aneurysm sac. This finding contrasts with conventional methods that often provide only structural evidence of a potential leak. The data suggest that the combination of these two imaging modalities offers a robust diagnostic framework. These results represent the first successful attempt to characterize such vascular complications using this advanced magnetic resonance approach.

Conclusions:

The authors demonstrate that 4D flow magnetic resonance imaging provides a viable pathway for characterizing type I endoleaks. This technique integrates spatial resolution with temporal velocity data to enhance diagnostic precision. Synthesis of these findings suggests that combining 4D flow with traditional angiography improves the identification of vascular complications. The study implies that clinicians might gain a deeper understanding of hemodynamic forces within the aneurysm sac. Future clinical workflows could benefit from the detailed flow profiles captured by this methodology. The researchers propose that this approach offers a unique perspective compared to standard cross-sectional imaging tools. This work highlights the potential for advanced imaging to refine the management of patients after aneurysm repair. These observations provide a foundation for larger investigations into the long-term efficacy of this diagnostic strategy.

The researchers propose that 4D flow MRI identifies endoleaks by integrating 3D anatomical resolution with time-resolved velocity measurements. This dual-data approach allows for the visualization of blood flow patterns that standard cross-sectional imaging, such as traditional magnetic resonance angiography, often fails to capture during routine post-repair surveillance.

The study utilizes 4D flow magnetic resonance imaging, which provides temporally resolved velocity data. This is paired with a traditional magnetic resonance angiogram to establish a comprehensive view of the vascular environment, contrasting with the limited temporal information provided by static computed tomography scans.

The authors suggest that the temporal resolution of velocity data is necessary to distinguish the dynamic flow of a type I endoleak from static anatomical structures. This requirement distinguishes the proposed method from conventional ultrasound, which lacks the full three-dimensional spatial context provided by this advanced MRI technique.

The 4D flow data acts as a functional overlay, providing dynamic hemodynamic information that complements the structural details of the magnetic resonance angiogram. While the angiogram defines the vessel boundaries, the flow data quantifies the speed and direction of blood movement within the leak.

The researchers measure blood velocity profiles within the aneurysm sac to characterize the leak. This phenomenon of high-velocity flow is distinct from the stagnant blood typically observed in successfully excluded aneurysms, allowing for a clearer differentiation between stable and unstable repair sites.

The authors propose that this imaging strategy enhances the accuracy of endoleak characterization. They suggest that this improved diagnostic capability may lead to better clinical decision-making compared to relying solely on traditional imaging modalities that lack comprehensive hemodynamic mapping.