Related Experiment Video
Updated: Jun 25, 2026

Façade-Level Monitoring of CO2 Variability under Urban Heat Island Conditions using Low-Cost Sensor Data Loggers
Published on: December 12, 2025
The influence of meteorological parameters on indoor radon in selected traditional Kenyan dwellings
M W Chege1, I V S Rathore, S C Chhabra
1Department of Physics, Kenyatta University, Nairobi, Kenya.
Abstract:
The effects of outdoor temperature, rainfall and wind speed on the indoor radon concentration in four types of traditional hut in Kenya were investigated by performing short-term (about 48 h) measurements with activated charcoal canisters. The concentrations vary widely (30.2-315.4 Bq m(-3)) during the study period, and the overall mean is 170.3 +/- 39.6 Bq m(-3). The indoor radon concentration correlates negatively with both the outdoor temperature (R(2) = 0.06) and the wind speed (R(2) = 0.11) but positively with rainfall (R(2) = 0.03). The results showed that changes in meteorological parameters cause more variations in indoor radon concentrations than the differences in the buildings' characteristics (i.e., designs, materials, etc). However, these variations are not significant (at 1% significance level).
More Related Videos
09:33Visualizing Field Data Collection Procedures of Exposure and Biomarker Assessments for the Household Air Pollution Intervention Network Trial in India
Published on: December 23, 2022
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
Related Concept Videos
Conduction, Convection and Radiation: Problem Solving
In order to solve a problem related to heat transfer, first of all, the situation needs to be examined to determine the type of heat transfer involved. This could...
Measurement of Air Content in Concrete
The pressure method,...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...