Haemoassist--a hand-held electronic patient diary for haemophilia home care

W Mondorf1, B Siegmund, R Mahnel

  • 1Haemostas--Praxis und Labor zur Diagnostik von Blutgerinnungsstörungen, Frankfurt, Germany. wmondorf@web.de

On-demand or prophylactic home-treatment is currently the treatment of choice for haemophilia patients. To allow physicians to monitor the amount of factor concentrates administered, the patients document each factor injection in a paper-diary. Nevertheless, because of the fact that most patients visit their physicians only two to four times a year, there could be considerable delay in detecting medication problems. The aim of this pilot study was to assess whether an electronic documentation tool could successfully replace traditional paper-diaries for haemophilia A patients and enable the physician to have a timely overview of the patient's treatment. An electronic, hand-held documentation tool, Haemoassist, was developed. In this study, patients using prophylaxis and on-demand therapies documented their factor consumption both electronically and on paper-diaries. Documentations were compared and descriptively evaluated. Patients also completed a survey to evaluate the feasibility and gather their opinions on the Haemoassist system. Ten patients from two haemophilia treatment centres in Germany submitted a total of 548 records via hand-held device during the observation period, from March 2006 to February 2007. Comparison of electronic and paper-based records showed differing responses among patients with some patients entering more electronic and some others more paper-based documentations. In the questionnaires on feasibility and usefulness of Haemoassist, three patients preferred the electronic tool, two patients wanted to continue using paper-based diaries, and one had no preference. The study shows that an electronic documentation system is feasible for haemophilia patients and provides the physician with the opportunity to more closely monitor patients. However, not all patients seem to be qualified for using an electronic tool, and the tool has to run reliably without major errors for ensuring reliability and acceptability. In the future, Haemoassist might support quality assurance in haemophilia treatment and improve guidance in the home-care setting.

Related Concept Videos

Holter Monitor: 24-Hour Monitoring01:23

Holter Monitor: 24-Hour Monitoring

Holter monitoring is a continuous electrocardiography (ECG) recording that tracks the heart's electrical activity over an extended period, generally 24 to 48 hours. This noninvasive diagnostic tool detects irregular heart rhythms that may not be captured during a standard ECG performed in a clinical setting.DeviceThe Holter monitor is a portable, small device connected to several electrodes on the patient's chest. These electrodes detect the heart's electrical signals and transmit them to the...
Assessing Blood pressure in the Leg01:11

Assessing Blood pressure in the Leg

Proper measurement of leg blood pressure is a critical skill for healthcare providers, ensuring precise and reliable readings. When performed correctly, this procedure informs patient care and enhances the efficacy of interventions. The following text outlines step-by-step guidelines to measure blood pressure in the leg, providing clarity and ease of understanding for practitioners.
Preparation:
Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation