Related Experiment Video
Updated: Jun 25, 2026

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Radial compression guided by mean artery pressure versus standard compression with a pneumatic device (RACOMAP)
Jose M Cubero1, Juan Lombardo, Carmela Pedrosa
1Cardiology Service, Valme University Hospital, Seville, Spain. josucubero@yahoo.es
Background:
Transradial access is the approach of choice in many laboratories for diagnostic coronariography or percutaneous coronary interventions (PCI) because of its lower vascular complication rate than the femoral approach. However, this approach has a higher rate (5-10%) of asymptomatic radial artery (RA) occlusion.
Methods:
We conducted a prospective, controlled, single-centre trial study. We investigated whether the pneumatic compression (using "TR Band of Terumo") of the radial artery guided by the mean artery pressure (MAP) after the procedure (group A) is efficient in reducing radial occlusion in patients under a coronary angiography by transradial access for diagnostic coronariography or PCI compared to use of standard procedure (group B, 15 cm(3) of air in the device).
Results:
The study was suspended after analyzing the results of 50% of the scheduled patients. An analysis of the results of 351 consecutive random patients in Group A showed significantly (P = 0.0001) lower rate (1.1%) of occlusion than Group B (12.0%) without significant differences in the rate of other complications. Other variables associated with RA occlusion in univariate analysis were previous or active smoker (P < 0.04), absence of anti-aggregant treatment (P < 0.04), and the presence of RA flow postprocedure (PFP, P < 0.001). Independent predictors with logistic regression analysis were PFP (HR = 0.06, 95% CI 0.01-0.2), presence of hematoma (HR = 3.7, 95% CI 1.2-11.0), and standard pneumatic compression in group B patients (HR = 18.8, 95% CI 3.8-92.2).
Conclusions:
Use of pneumatic compression guided by MAP is safe and efficient, and it can significantly lower the incidence of radial artery occlusion.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...

