Related Experiment Video
Updated: Jun 25, 2026

A Toolkit to Enable Hydrocarbon Conversion in Aqueous Environments
Published on: October 2, 2012
A sensitive fluorescence reagent for the determination of aldehydes from alcoholic beverage using high-performance
Jinmao You1, Tao Yan, Huaixin Zhao
1Northwest Plateau Institute of Biology, Chinese Academy of Sciences, Xining 810001, PR China. Jmyou6304@163.com
Abstract:
A pre-column derivatization method for the sensitive determination of aldehydes using the tagging reagent 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxy] ethyl carbonylhydrazine (DBCEEC) followed by high-performance liquid chromatography with fluorescence detection and APCI-MS identification has been developed. The chromophore of fluoren-9-methoxy-carbonylhydrazine (Fmoc-hydrazine) reagent was replaced by 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxy] ethyl functional group, which resulted in a sensitive fluorescence tagging reagent DBCEEC. DBCEEC could easily and quickly labeled aldehydes. The maximum excitation (300nm) and emission (400nm) wavelengths did not essentially change for all the aldehyde derivatives. Derivatives were sufficiently stable to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z [M+(CH(2))(n)](+) in positive-ion mode (M: molecular weight of DBCEEC, n: corresponding aldehyde carbon atom numbers). The collision-induced dissociation of protonated molecular ion formed fragment ions at m/z 294.6, m/z 338.6 and m/z 356.5. Studies on derivatization demonstrated excellent derivative yields in the presence of trichloroacetic acid (TCA) catalyst. Maximal yields close to 100% were observed with a 10 to 15-fold molar reagent excess. Separation of the derivatized aldehydes had been optimized on ZORBAX Eclipse XDB-C(8) column with aqueous acetonitrile as mobile phase in conjunction with a binary gradient elution. Excellent linear responses were observed at the concentration range of 0.01-10nmolmL(-1) with coefficients of >0.9991. Detection limits obtained by the analysis of a derivatized standard containing 0.01nmolmL(-1) of each aldehyde, were from 0.2 to 1.78nmolL(-1) (at a signal-to-noise ratio of 3).
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
NMR Spectroscopy and Mass Spectrometry of Aldehydes and Ketones
Mass Spectrometry: Alcohol Fragmentation
Mass Spectrometry: Aldehyde and Ketone Fragmentation
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...