Related Experiment Video
Updated: Jun 25, 2026

A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
A simple, lightweight CPAP-delivery device, composed of a three-way stopcock, for the nondependent lung
Hiroshi Sasano1, Nobuko Sasano, Shoji Ito
1Department of Anesthesiology and Medical Crisis Management, Nagoya City University Graduate School of Medical Sciences, Mizuho-ku, Nagoya, 467-8622, Japan.
Purpose:
We aimed to introduce a simple, lightweight continuous positive airway pressure (CPAP)-delivery device for the nondependent lung during one-lung ventilation, to investigate how the type of three-way stopcocks, and the compliance and resistance of a test lung affect the relationship between the oxygen flow rate and CPAP level produced, and to examine how the device works in a clinical setting.
Methods:
In the test lung study, the bronchial blocker of a Univent tube was connected to a test lung. The effects of oxygen-flow rate, types of three-way stopcocks, and compliance and resistance of the test lung on the CPAP levels were studied. In the clinical study, the lightweight device was used to treat hypoxia in seven patients during one-lung ventilation with the bronchial blocker.
Results:
In the test lung study, the CPAP level produced by the device was proportional to the oxygen-flow rate, dependent on the type of three-way stopcock used, and independent of the compliance or resistance of the test lung. There was no discrepancy between the plateau pressures of the test lung and the monitoring port of an additional stopcock at any degree of compliance or resistance of the test lung at any oxygen-flow rate. Therefore, the relationship between the oxygen-flow rate and CPAP level can be ensured in advance before application to the lung, with an additional three-way stopcock of which the distal end is occluded. In the clinical study, peripheral oxygen sataration Sp(O2) improved while the CPAP level ranged from 2.8 to 5.4 cmH2O.
Conclusion:
The lightweight CPAP delivery-device can provide variable CPAP levels by adjusting the oxygen-flow rate without real-time monitoring of the pressure.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Inhaled Medications