Related Experiment Video
Updated: Jun 25, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
Physiological effects of different interfaces during noninvasive ventilation for acute respiratory failure
Amanda Tarabini Fraticelli1, François Lellouche, Erwan L'her
1Service de Réanimation Médicale, Groupe Hospitalier Albert Chenevier Henri Mondor, Créteil, France.
Objective:
To test the short-term physiologic effects (indexes of respiratory effort, ventilation, and gas exchange), leaks, patient-ventilator asynchrony, and comfort of four noninvasive ventilation (NIV) facial, oronasal, or oral interfaces with major differences in internal volume.
Design:
Prospective, short-term, crossover randomized physiologic study.
Setting:
Medical intensive care unit in a university hospital.
Patients And Participants:
Fourteen consecutive patients receiving NIV for either hypoxemic (n = 7) or hypercapnic (n = 7) acute respiratory failure.
Interventions:
Four interfaces, tested randomly over consecutive sequences, had very high (977 mL), high (163 mL), moderate (84 mL), or virtually no internal volume (mouthpiece). The pressure level was increased in two patients with the larger mask, and was decreased in all patients when using the mouthpiece.
Measurements And Main Results:
Despite differences in internal volume, no apparent dead space effect was observed on minute ventilation, work of breathing, or arterial CO2 levels. Compared with baseline, NIV was uniformly successful in reducing indexes of respiratory effort: the pressure-time product of the respiratory muscles decreased from a median (25th-75th interquartile range) of 179 (158-285) cm H2O.sec.min to values between 91 and 111 during NIV, with no differences between masks (p = 0.84). Few differences were observed in terms of arterial blood gases and breathing pattern. Leaks and patient-ventilator asynchronies were greater with the mouthpiece, and comfort with this interface was deemed poor for most patients.
Conclusion:
The internal volume of the masks had no apparent short-term dead space effect on gas exchange, minute ventilation, or patient's effort, suggesting that, with the exception of mouthpiece, interfaces may be interchangeable in clinical practice provided adjustment of the ventilatory device parameters are performed.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Acute Respiratory Failure-IV
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
