Discrimination of bacteria using pyrolysis-gas chromatography-differential mobility spectrometry (Py-GC-DMS) and
William Cheung1, Yu Xu, C L Paul Thomas
1School of Chemistry, Manchester Interdisciplinary Biocentre, University of Manchester, 131 Princess Street, Manchester, UKM1 7DN.
Abstract:
Discrimination of bacteria was investigated using pyrolysis-gas chromatography-differential mobility spectrometry (Py-GC-DMS). Three strains belonging to the genus Bacillus were investigated and these included two strains of Bacillus subtilis and a single Bacillus megaterium. These were chosen so as to evaluate the possibility of bacterial strain discrimination using Py-GC-DMS. The instrument was constructed in-house and the long-term reproducibility of the instrument was evaluated over a period of 60 days using a Scotch whisky quality control. To assess the reproducibility further each bacterium was cultured six times and each culture was analysed in replicate to give three analytical replicates. The DMS data were generated in both positive and negative modes, and the data in each mode were analysed independently of each other. The Py-GC-DMS data were pre-processed via correlation optimised warping (COW) and asymmetric least square (ALS) to align the DMS chromatograms and to remove any unavoidable baseline shifts, prior to normalisation. Processed chromatograms were analysed using principal component analysis (PCA) followed by supervised learning methodology using partial least squares for discriminant analysis (PLS-DA). It was found that the separations between B. subtilis and B. megaterium can be readily observed by PCA; however, strain discrimination within the two B. subtilis was only possible using supervised learning. As multiple biological replicates were analysed an exhaustive splitting of the training and test sets was undertaken and this allowed correct classification rates (CCRs) to be assessed for the 3375 test sets. It was found that with PLS-DA the negative ion mode DMS data were more discriminatory than the positive mode data.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
08:07A Two-Step Pyrolysis-Gas Chromatography Method with Mass Spectrometric Detection for Identification of Tattoo Ink Ingredients and Counterfeit Products
Published on: May 22, 2019
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...