Related Experiment Video
Updated: Jun 25, 2026

A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
X-ray absorption spectroscopy of VOCl3, CrO2Cl2, and MnO3Cl: an experimental and theoretical study
G Fronzoni1, M Stener, P Decleva
1Dipartimento di Scienze Chimiche, Universita di Trieste, Via L. Giorgieri 1, 34127 Trieste, Italy. fronzoni@univ.trieste.it
Abstract:
X-ray absorption spectra of gas-phase VOCl(3) and CrO(2)Cl(2) have been measured in the metal L(2,3)-edge and O K-edge regions. The assignment of the spectral features is based on the relativistic two-component ZORA TDDFT approach. The calculations provide results in excellent agreement with the experimental spectra and prove the importance of including both configuration mixing and spin-orbit coupling in the theoretical description to obtain a reliable simulation of the transition metal L(2,3)-edge. The calculations are extended also to the MnO(3)Cl molecule to discuss the spectral variations along the series of the oxychlorides both in the metal L(2,3) and ligand O K spectra.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...

