Vapour-phase hydrogen peroxide inactivates Yersinia pestis dried on polymers, steel, and glass surfaces
J V Rogers1, W R Richter, M Q Shaw
1Battelle Biomedical Research Center, 505 King Avenue, JM-7, Columbus, OH 43201, USA. rogersjv@battelle.org
Aims:
This study evaluated the inactivation of virulent Yersinia pestis dried on polymers, steel, and glass surfaces using vapour-phase hydrogen peroxide.
Methods And Results:
A suspension of Y. pestis CO92 (1.70 x 10(8) CFU) was dried on 10 different types of test surfaces and exposed to vapour-phase hydrogen peroxide fumigation for a contact time of 2 h. A significant reduction in the log10 CFU of Y. pestis on all 10 materials was observed between the controls evaluated after a 1 h drying time and unexposed controls evaluated after the decontamination run. Qualitative growth assessment showed that vapour-phase hydrogen peroxide exposure inactivated Y. pestis on all replicates of the 10 test materials as well as biological indicators up to 7 days postexposure.
Conclusions:
Virulent Y. pestis CO92 is inactivated on polymers, steel, and glass surfaces when exposed to vapour-phase hydrogen peroxide without observable physical damage to the test materials.
Significance And Impact Of The Study:
This study provides information for using vapour-phase hydrogen peroxide as a practical process for the decontamination of virulent Y. pestis in circumstances where time-dependent attenuation/inactivation orliquid/heat decontamination may not be the most suitable approach.
More Related Videos
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
14:17The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Chemical Agents for Microbial Control
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Autoxidation of Ethers to Peroxides and Hydroperoxides
Hand hygiene
Hand washing...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration