Related Experiment Video
Updated: Jun 25, 2026

The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
Saline flush test for bedside detection of misplaced subclavian vein catheter into ipsilateral internal jugular vein
G P Rath1, P K Bithal, G R Toshniwal
1Department of Neuroanaesthesiology, Neurosciences Center, All India Institute of Medical Sciences, New Delhi, India. girijarath@yahoo.co.in
Background:
The most common misplacement during subclavian vein (SCV) catheterization is into the ipsilateral internal jugular vein (IJV). Chest radiography is the gold standard for the confirmation of correct placement. However, it is time-consuming and has the disadvantage of radiation exposure. We assessed the sensitivity and specificity of our previously reported 'flush test' for confirming correct central line placement.
Methods:
All neurosurgical patients who underwent successful SCV catheterization on the right side by an infraclavicular approach were enrolled in this study. The flush test was performed by injecting 10 ml of normal saline in the distal port of catheter, while anterior angle of ipsilateral neck was palpated by an independent observer. A thrill of fluid elicited on the palm of hand (positive test) was suggestive of misplaced catheter into ipsilateral IJV. This was confirmed with chest fluoroscopy.
Results:
SCV catheterization was performed in 570 patients. The flush test was positive in 19 patients (3.3%) and negative in 551 patients (96.7%). There were 26 (4.6%) misplacements as detected by chest radiography; 19 entered the IJV (3.3%) and seven the contralateral SCV (1.2%). In all patients who had a misplaced catheter into the ipsilateral IJV, the flush test results were positive, whereas the results were negative in patients who had normally placed catheter or misplaced catheter elsewhere. It was found that the test had 100% sensitivity and specificity to detect misplacement of SCV catheter into the ipsilateral IJV.
Conclusions:
Saline flush test is a simple and sensitive bedside test that successfully detects misplaced SCV catheters into ipsilateral IJV.
More Related Videos
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Imaging Studies VII: Vascular Imaging
Venous Thrombosis III: Interprofessional Care