Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
Measuring concentrations of ammonia in ambient air or exhaust air stream using acid traps
P M Ndegwa1, V K Vaddella, A N Hristov
1Biological Systems Engineering, Washington State Univ., P.O. Box 646120, Pullman, WA 99164, USA. ndegwa@wsu.edu
Abstract:
Strong acid solutions have been widely used in acid traps to determine concentrations of ammonia in ambient air or exhaust air stream. A literature survey indicates the method has a long history and a wide variation in use. Through a series of studies, this paper examines several factors including volume of the acid, depth of the acid, and airflow rate; that might affect the efficiency of sulfuric acid traps and recommends steps researchers and other users may take to ensure reliable results from this method. The results from these series of studies indicate: (i) an inverse relationship between the efficiency of the acid traps and the amount of ammonia to be trapped even when the capacity of the acid trap is excessively greater than the maximum theoretical stoichiometric capacity needed to dissolve all of the ammonia, (ii) for the same volume of acid, the efficiency of the acid trap increased with the acid depth but overall, the efficiency at any given acid depth decreased as the amount of ammonia through the trap increased, and (iii) at the two airflow rates examined in this study (0.5 and 1.0 L/min) the efficiency of the acid traps decreased at similar rates as the concentration of ammonia in the sample air increased but the efficiency of the trap was significantly higher at the lower airflow rate. To obtain reliable measurements from this method, therefore, multi-point calibrations within the entire range of target measurements is recommended to provide accurate corrections of the measurements.
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
High-Performance Liquid Chromatography: Types of Detectors
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Atomic Absorption Spectroscopy: Atomization Methods
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...